Professional generator ENDRESS ESE 1308 DBG 13 kVA – Robust generator with electric start for continuous operation.
Call For Price
| Size | XS | S | M | L |
|---|---|---|---|---|
| Euro | 32/34 | 36 | 38 | 40 |
| USA | 0/2 | 4 | 6 | 8 |
| Bust(in) | 31-32 | 33 | 34 | 36 |
| Bust(cm) | 80.5-82.5 | 84.5 | 87 | 92 |
| Waist(in) | 24-25 | 26 | 27 | 29 |
| Waist(cm) | 62.5-64.5 | 66.5 | 69 | 74 |
| Hips(in) | 34-35 | 36 | 37 | 39 |
| Hips(cm) | 87.5-89.5 | 91.5 | 94 | 99 |
With your arms relaxed at your sides, measure around the fullest part of your chest.
Measure around the narrowest part of your natural waist, generally around the belly button. To ensure a comfortable fit, keep one finger between the measuring tape and your body.
Professional generator ENDRESS ESE 1308 DBG 13 kVA – Robust generator with electric start for continuous operation. Generator ESE 1308 DBG ES DUPLEXsilent
Features:
- Automatic shutdown in case of low engine oil level
- Alternator overload protection
- Made according to DIN 14685
- 3-stage fuel supply valve
- Tool case
- Foldable handles for easy transport
- Ground test line
- Fuel level indicator
- Insulation monitoring - without shutdown
- Multifunctional control panel E-MCS 4.0 (fuel level, ground fault, engine oil pressure, load on sockets, ...)
- ECOtronic operating mode that reduces consumption and noise (optional)
- FireCAN connection for remote control of the generator, e.g. at the vehicle pump or the car ladder basket (option)
- Electric engine start
Technical data:
- Power [PRP] kVA / kW 3 ~: 13.2 / 10.6
- Power [PRP] kVA / kW 1 ~: 7.2 / 6.5
- Rated voltage 3 ~: 400 V
- Rated voltage 1 ~: 230 V
- Rated current 3 ~: 19.1 A
- Rated current 1 ~: 31.3 A
- Power factor (Ph): 0.8
- Frequency: 50 Hz
- Protection class: IP 54
- Voltage regulation: electronic
- Engine type: B&S Vanguard
- Number of cylinders in the engine: 2
- Engine displacement: 627 ccm
- Engine output power at 3000 rpm: 15.0 kW
- Fuel: petrol
- Tank capacity (l): 12
- Consumption l / h at 75% load: 3.5
- Operating time (h) with one tank at 75% load (approx.): 3.5
- Starting system: electronic
- Sound power level LWA dB (A): 92
- Sound pressure level (7 m) dbA): /
- Approx. weight (kg): 144
- Dimensions L x W x H (mm): 820 x 440 x 580
- Sockets: 3 x 230V 16A, 2 x 400V CEE 16A
Duplex operating system
Once upon a time:
When generators did not yet have built-in electronics, we used asynchronous generators to produce so-called "clean" electricity, and synchronous generators to overcome "difficult starts".
Today:
With DUPLEX technology, the electronic controller individually switches between the two drive systems according to needs, thus protecting the motor from overload. Power reserves are generated, the DUPLEX generator will drive both voracious and sensitive consumers and at the same time protect them from damage. Thus, all the advantages of asynchronous and synchronous generators are combined in the DUPLEX system. The discussion of whether it is better to have asynchronous or synchronous technology is also refuted.
Advantages in one place:
- Combines and strengthens all the advantages of asynchronous and synchronous generators
- VKS technology (wear-free, contact-free, interference-free)
- Simultaneous use of electronic and inductive loads
- Electronically controlled brushless synchronous generator
- Brushless technology - thus achieving up to 20,000 hours of use
- Generator made according to IP54 standard, thus dust and drip-proof
- 200% suitable for asymmetrical loads under real conditions
- Voltage stability +/-1% with 3 users
- Up to 4x stronger starting current
- 100% use without short circuits
- Disturbance factor ≤ 5%